z transmitters, Pressure Sensors

Z Series Transmitters


Pressure transmitters for pressure and absolute pressure.

Application

These transmitters are used to measure the absolute and relative pressures or the level of liquids and gases, and steam.

They are used in the chemical, pharmaceutical and food industries, in mechanical engineering, shipbuilding, water supply and conservation.

Design

The pressure transmitters contain a thin-film cell with ceramic diaphragm which can be used for corrosive media, and an electronics board, fitted together in a stainless steel housing.

The transmitter has a process connection G½A (male thread), to DIN 16 288 made of stainless steel. The electrical connection is via a plug (DIN 43 650) with Pg 9 cable inlet.

Mode of operation

The transmitters have a thin-film strain gauge which is mounted on a ceramic diaphragm. Every measuring cell is temperature-compensated.

The voltage output by the measuring cell is converted by an amplifier into an output current of 4 to 20 mA.

Technical Data

Application              7MF1563 
Mode of operation and system design
Measuring principle
 Thin-film strain gauge
Input  
 Measured variable Pressure and absolute pressure
 Measuring range 0 to 400 bar 
 Output  
 Output signal  
 Load  
 Characteristic  
 Accuracy  
 Error in measurement (at 25°C including conformity error, hysteresis and repeatability) 0.25% of full-scale value-typical 
 Response time T99 Long-term drift  
 *Start-of-scale value 0.25% of full-scale value/year
 *Span 0.25% of full-scale value/year 
 Ambient temperature effect  
 *Span  0.25% of full-scale value
 Vibration influence  
 Power supply influence  
 Rated operating conditions  
 *Ambient conditions  -25 to + 85°C
 *Storage temperature  -0 to + 100°C
 *Degree of protection (to EN 60 529)  IP 65
 *Electromagnetic compatibility  
 - Emitted interference  To EN 50 081
 - Noise immunity  To EN 50 082
 Medium Conditions  
 * Process temperature limits  -30°C to + 120°C
 * Process pressure limits  See overload pressure
 Design  
 Weight (without options) Dimensions Material  Approx 0.25 kg
 *Wetted parts materials  A12O 3 - 96%
 - Measuring cell  Stainless steel, mat. No. 
 - Process connection  1, 4571
 - O-ring  Viton
 *Non-wetted parts materials  
 - Housing   Stainless steel, mat. No. 
 - Plug connector  1, 4571
Process connections G ½ A - male thread
  G ½ A - female thread
Power Supply  
Terminal voltage on transmitter 10 - 36 V DC