The High-Accuracy, Fit-Anywhere Venturi Flowmeter.
The V-Cone is an advanced differential pressure-type flowmeter, ideal for tight-fit and retrofit installations. Employed in today's most challenging applications, it offers users high accuracy and repeatability, extremely flexible installation and no maintenance. The installation flexibility of the V-Cone Venturi meter is due to its ability to condition the flow prior to measurement. It has been employed successfully in oil and natural gas production and distribution, process and facility control, and the municipal water/wastewater sector.
With no moving parts to replace or maintain, the V-Cone Venturi meter offers long term performance with low operating costs. In addition, the meter never needs recalibration, so once installed, it can operate unattended for years. All these benefits add up to a great flowmeter for your toughest and tightest applications, when high accuracy and repeatability are a must.
- No straight pipe runs
- Pre-conditions flow
- Repeatability to 0.1%
- Accuracy to +/- 0.5%
- Low headloss
- Low maintenance
- No recalibration
The V-Cone Venturi meter is a differential pressure type flowmeter with a unique design that conditions the flow prior to measurement.
- Differential pressure is created by a cone placed in the centre of the pipe.
- The cone is shaped so that it "flattens" the fluid velocity profile in the pipe, creating a more stable signal across wide flow downturns.
- Flow rate is calculated by measuring the difference between the pressure upstream of the cone at the meter wall and the pressure downstream of the cone through its centre.
The V-Cone Venturi flowmeter is available in a wide variety of configurations to meet the requirements of ANSI, DIN and JIS standards. Use the following table to find the model, configuration and size best suited to your application.
| MODELS |
CONFIGURATION |
SIZES |
| VB |
Beveled Ends |
0.5" - 60" |
| VP |
Plain Ends |
0.5" - 60" |
| VT |
Threaded Ends |
0.5" - 6" |
| VS (L) |
ANSI B16.5 Raised Face Flanges - Class 150 or 300 |
0.5" - 24" |
| VS (H) |
ANSI B16.5 Raised Face Flanges - Class 600 or 900 |
0.5" - 24" |
| VS (X) |
ANSI B16.5 Raised Face Flanges - Class 120 or 250 |
30" - 60" |
| VW (L) |
ANSI B16.5 Weld Neck, Raised Face Flanges - Class 150 or 300 |
0.5" - 24" |
| VW (H) |
ANSI B16.5 Weld Neck, Raised Face Flanges - Class 600 or 900 |
0.5" - 24" |
| VQ (L) |
ANSI B16.5 RTJ Slip-On Flanges - Class 150 or 300 |
0.5" - 24" |
| VR (L) |
ANSI B16.5 RTJ Weld Neck - Class 150 or 300 |
0.5" - 24" |
| VR (H) |
ANSI B16.5 RTJ Weld Neck - Class 600 or 900 |
0.5" - 24" |
| VC |
DIN Slip-On Flat Face Flanges |
0.5" - 24" |
| VJ |
JIS Slip-On - 10k or 20k |
0.5" - 24" |
| VI |
Insertion Saddles with ANSI Slip-On, Raised Face Flanges |
6" - 36" |
| VD |
Weld Neck Flanges - DIN 2633 (PN16) or DIN 2635 (PN40) |
0.5" - 24" |
Sizes larger than 24" are available on most models on request.
- Each V-Cone is sized for the intended application. Specific performance ratings are obtained through the sizing process.
- For dimensional data, materials of construction, pipe schedules, testing procedures and fitting options, contact McCrometer direct on 1-951-652-6811 or call your nearest McCrometer representative.
The following flow and installation parameters will help you decide whether the V-Cone is suited to your specific flow measurement application. Alternatively, fill out the Free Flow Evaluation Form and let McCrometer's sales engineers assist you in choosing the best flowmeter for your needs.
| Types of flow measured |
Clean, dirty or disturbed liquid or gas flows; dry or wet gas; condensate; abrasive flows |
| Accuracy |
+/-0.5%, depending on application |
| Repeatability |
+/-0.1% |
| Turndown |
10:1, can be up to 30:1 for some applications |
| Operating temperature |
Depends on materials of construction |
| Operating pressure |
Depends on materials of construction |
| Head loss |
Low headloss, varies with beta ratio and DP |
Installation Parameters
| Pipeline sizes |
0.5 - 120" or greater |
| Process connector |
Flanged; threaded; hub or weld-end; others on request |
| Upstream/downstream pipe runs |
0-3 dia upstream; 0-1 dia downstream |
| Other |
Three or five valve manifold recommended |
The V-Cone is an advanced differential pressure flowmeter with a unique design for conditioning flow prior to measurement.
- Standard Accuracy: From +/-0.5% of actual flow (certain fluids and Reynolds number require specific calibrations to achieve this value).
- Repeatability: +/-0.1% or better.
- Flow Ranges: 10:1 and greater.
- Standard Beta Ratios: 0.45 to 0.80, special betas available.
- Head Loss: Varies with beta ratio and DP.
- Installation Piping Requirements: 0-3 diameters upstream and 0-1 diameters downstream of the cone are required, depending on fittings or valves in the adjacent pipeline.
- Materials of Construction Include: Duplex 2205, 304, or 316 stainless steel, Hastelloy C-276, 254, SMO, carbon steels. Special materials on request.
- Line sizes: 0.5" to 120" or larger.
- End Fittings: Flanged, threaded, hub or weld-end standard. Others on request.
- Configurations: Precision flow tube, wafer-type, insertion weld-on saddle with removable top plate.
- Calibrated for customer application.
- No moving parts.
- ASME B31.3 construction available.
- Canadian custody transfer approved.
- Meters in compliance with PED9723EC are available upon request.
- The V-Cone is manufactured under a quality management system that is certified to ISO 9001:2000.
|