HTA

Portable Thermal Mass Flow Meters

 
 
 
 

Not quite the right specs for you?

Provide us with the specifics of your application and we will target a solution for you.

Submit your specs for

application assistance

 

Product details 

 

 

HTA

  • Hand-held instrument with IP64 type of protection to which all Höntzsch TA sensors with thin-film sensor element can be connected.
  • High-contrast LCD display, measured value display 13 mm high four-digit with decimal point as well as affiliated display unit, display of duration of measurement in seconds 6 mm high, adjustment and configuration instructions, operator's information, status display 3 mm high.
  • Interface RS232 for direct transfer of the stored measured values to a PC.
  • Instantaneous values every second. Display of standard velocity v, standard volume flow V/t or temperature (resolution 1 °C), selectable. Display of instantaneous value in the START and also START/STOP mode also with long-term measurement. Display units: m/s, m³/h, l/min, °C.
  • Power supply by 9V battery or plug-in power supply.
  • Analogue output 0 . 4 V = 0 . x m/s .
  • Data and measured value storage for 500 data records. When being stored the data records are automatically marked with a group number (max. 99) and serial number.
  • Optional accessories: RS232 / V24 adapter for data transmission to an IBM compatible PC / µP-Flowtherm extension cable 3 m or 5 m long, also with waterproof connector / µP-Flowtherm Y cable for connection to two sensors at the input of the µP-Flowtherm / µP-Flowtherm carrying case / µP- Flowtherm light metal carrying case / 9 V battery.

 

Components / Downloads

 

 

ref

description

downloads

HTA

General Specification

 

General Spec