Specialists in flow measurement

Flow Meter

& Flow Measurement Solutions

Tel:  0208 207 6565     Email sales@flowline.co.uk  

 

Search

home     contact us     sitemap    application centre

Products

 

Clamp on Ultrasonic Flow Meters

 
 

Differential Pressure Flow Meters

 
 

Electromagnetic Flowmeters

 
 

Open Channel Radar Flowmeters

 
 

Thermal Mass Meters

 
 

Data Loggers, ATEX, Web Enabled

 
 

Flow Computers

 
 

Flow Switches

 
 

Level Measurement

 
 

Mass Flow Meters

 
 

Pressure Sensors

 
 

Samplers

 
 

Turbine Meters

 
 

VA Meters

 
 

Vortex Meters

 
 

Ultrasonic Thickness Gauges

 

Flowmeter Hire

 

Application Centre

 
 
   
 

Pressure Sensors \ Process Transmitters \ DSIII Series

 

DSIII Series

Pressure transmitters for pressure, absolute pressure, differential pressure, flow and level.

 
 
 
 

Not quite the right specs for you?

Provide us with the specifics of your application and we will target a solution for you.

Submit your specs for

application assistance

 

Product details 

 

 

Application

Various versions of the DSIII series are available with a two-wire circuit. The output signal is a load-independent direct current of 4 to 20 mA linearly proportional to the input pressure.

Transmitters conforming to the type of protection 'Intrinsic safety' and 'Explosion-proof' may be installed within potentially explosive atmospheres (zone 1 or zone 0). The transmitters are provided with an EU prototype test certificate and comply with the corresponding harmonized European standards of the CENELEC. Transmitters with the type of protection 'Intrinsic safety' for use in zone O may be operated with power supply units of category "1a" and "1b".

The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances.

The transmitters can be programmed locally using three input keys or externally via HART. The following table describes the fundamental parameters. Further parameters for special applications are accessible via HART.

Transmitter for pressure

This type of transmitter measures the pressure of corrosive and non-corrosive gases, vapours and liquids. Spans are possible from 0.01 to 400 bar.

Pressure limit of medium for pressure transmitters

Span Upper pressure limit of medium
0.01 to 1 bar 6 bar
0.04 5o 4 bar 10 bar
0.16 to 16 bar 32 bar
0.63 to 63 bar 100 bar
1.601 to 160 bar 250 bar
4.00 to 400 bar 600 bar

Transmitter for absolute pressure

This type of transmitter measures the absolute pressure of corrosive and non-corrosive gases, vapours and liquids

Two series are available

  • "Pressure" series
  • "Differential pressure" series

The "Differential pressure" series has a higher pressure limit for the medium.

Spans are possible from 8.3 mbar to 160 bar.

Pressure limit of medium for absolute pressure transmitters from the differential pressure series

Span Upper pressure limit of medium
8.3 to 250 mbar 32 bar
43.0 to 1300 mbar 32 bar
160.0 to 5000 mbar 32 bar
1000.0 to 30000 mbar 160 bar
5300.0 to 160000 mbar 160 bar

Transmitter for differential pressure and flow

This type of transmitter is used to measure

  • the differential pressure
  • a small positive or negative pressure
  • the flow q - v ?p (together with a primary differential pressure device)

Spans are possible from 1mbar to 30 bar.

Pressure limit of medium for differential pressure and flow transmitters

Span Upper pressure limit of medium
1.0 to 20 mbar 32 bar
1.0 to 60 mbar 160 bar
2.5 to 250 mbar 160 bar
6.0 to 600 mbar 160 bar
16.0 to 1600 mbar 160 bar
50.0 to 5000 mbar 160 bar
300.0 to 30000 mbar 160 bar

Transmitter for level

This type of transmitter with mounting flange measures the level of corrosive and non-corrosive liquids in open or closed containers. Spans are possible between 25 mbar and 5 bar. The nominal mounting flange diameter is DN 80 or DN 100, or 3 or 4 inch.

In the case of level measurements in open containers, the low-pressure connection of the measuring cell remains open (measurement with respect to atmosphere), while for measurements in closed containers, this connection must be connected to the container in order to compensate the static pressure.

The wetted parts are constructed from a variety of materials depending on the degree of corrosion resistance required.

Span Upper pressure limit of medium
25 to 250 mbar Flange Limit
25 to 600 mbar Flange Limit
53 to 1600 mbar Flange Limit
160 to 5000 mbar Flange Limit

Design and mode of operation

The DSIII series is immediately ready for operation following installation. The adjustable span corresponds to the data on the rating plate. If a customer-specific setting is made in the factory, the start-of-scale and full-scale values are printed on the rating plate.

If necessary, the parameters can also be changed during commissioning using simple input operations on the transmitter.

 

 

Components / Downloads

 

 

ref

description

downloads