Flowmeter and Flow Measurement Solutions from Flowline Ltd

printer friendly page >>

Pressure transmitters for pressure and absolute pressure

Application

These transmitters are used to measure the absolute and relative pressures or the level of liquids and gases, and steam.

They are used in the chemical, pharmaceutical and food industries, in mechanical engineering, shipbuilding, water supply and conservation.

Design

The pressure transmitters contain a thin-film cell with ceramic diaphragm which can be used for corrosive media, and an electronics board, fitted together in a stainless steel housing.

The transmitter has a process connection G½A (male thread), to DIN 16 288 made of stainless steel. The electrical connection is via a plug (DIN 43 650) with Pg 9 cable inlet.

Mode of operation

The transmitters have a thin-film strain gauge which is mounted on a ceramic diaphragm. Every measuring cell is temperature-compensated.

The voltage output by the measuring cell is converted by an amplifier into an output current of 4 to 20 mA.

Technical Data

Application 7MF1563
Mode of operation and system design
Measuring principle
Thin-film strain gauge
Input
Measured variable Pressure and absolute pressure
Measuring range 0 to 400 bar
Output
Output signal
Load
Characteristic
Accuracy
Error in measurement (at 25°C including conformity error, hysteresis and repeatability) 0.25% of full-scale value-typical
Response time T99 Long-term drift
*Start-of-scale value 0.25% of full-scale value/year
*Span 0.25% of full-scale value/year
Ambient temperature effect
*Span 0.25% of full-scale value
Vibration influence
Power supply influence
Rated operating conditions
*Ambient conditions -25 to + 85°C
*Storage temperature -0 to + 100°C
*Degree of protection (to EN 60 529) IP 65
*Electromagnetic compatibility
- Emitted interference To EN 50 081
- Noise immunity To EN 50 082
Medium Conditions
* Process temperature limits -30°C to + 120°C
* Process pressure limits See overload pressure
Design
Weight (without options) Dimensions Material Approx 0.25 kg
*Wetted parts materials
- Measuring cell
- Process connection
- O-ring
A12O 3 - 96%
Stainless steel, mat. No. 1, 4571
Viton
*Non-wetted parts materials
- Housing
- Plug connector
Stainless steel, mat. No. 1, 4571
Process connections G ½ A - male thread
G ½ A - female thread
Power supply
Terminal voltage on transmitter 10 - 36 V DC